Philips Fortimo HBMt Gen 3 System Design In Guide 13
Controllability
Default dimming protocols
The Fortimo LED HBMt Gen3 module is dimmable with a range of integrated light
control options.
Adjustable Output Current
Constant Light Output
1-10 V, AmpDim, DALI and Dynadimmer dimming
Specic features will depend on the Philips Advance LED driver system selected
(Tables 2-3). Please visit www.philips.comledsystemsna for complete information
on the integrated light control options available in the Xitanium product range.
Constant Light Output
There are minimum light level requirements for public lighting. In order to
compensate for lumen depreciation, which occurs in all light sources over time, the
lighting design is often over-lit at the beginning of the source’s lifetime.
It is possible to deliver energy savings by avoiding over-lighting and still ensuring the
minimum expected light level over the lifetime of the module if the Constant Light
Output (CLO) feature in Xitanium Programmable drivers is used.
The CLO feature uses a predictive algorithm to increase the output current to the
module over the specied lifetime of 50,000 hours
*
. As the current increases, the
energy consumption also increases. The CLO feature can be combined with other
dimming protocols for even greater energy savings.
Programming CLO in Fortimo LED High Brightness Module Gen 3 will ensure
minimal light levels without wasting energy in the beginning of module’s life.
Please use Table 15 to program the CLO curve for Fortimo LED HBMt Gen3.
Table 15. Fortimo LED High Brightness Module CLO curve, all module types
Figure 17. Energy savings with CLO
Note: Although it is technically possible to dim Fortimo LED HBMt Gen3 modules
below 100mA, Philips does not specify product performance for modules operating
below this current.
Module working hours Power level
0 85%
4,000 86%
8,000 87%
12,000 89%
16,000 90%
20,000 91%
24,000 92%
28,000 93%
32,000 95%
36,000 96%
40,000 97%
50,00 100%
* Average rated life is based one engineering data testing
and probability analysis. The hours are at the B50, L70
point - 50,000 hours life with 70% lumen maintenance at
Tc point of 56°C for 3R and 61°C for 1R.